-
Original Article
-
Korean J Med. 2008;75(1):42-53.
- 원저 : 64절편 다검출기 CT 관상동맥 조영술을 이용한 관상동맥 질환 진단의 정확도
-
남궁준.최현민.권성욱.도준형.이성윤.허 감.이원로, , , , , ,
-
- Diagnostic accuracy of 64-slice multidetector CT coronary angiography for the evaluation of coronary artery disease
-
June Namgung, Hyunmin Choe, Sung Uk Kwon, Joon Hyung Doh, Sung Yun Lee, Gham Hur, Won Ro Lee
-
경희대학교 의과대학 순환기내과학교실
-
- Abstract
- Background/Aims
: Invasive coronary angiography remains the gold standard in the diagnosis of coronary artery disease. However, multidetector CT (MDCT) coronary angiography is an emerging technique that is available for the non-invasive detection of coronary artery stenoses. While the diagnostic accuracy of first generation MDCT is limited, recently released 64-slice MDCT has yielded promising results due to increased temporal and spatial resolution. The objective of this study was to investigate the diagnostic accuracy of non-invasive 64-slice MDCT for coronary artery disease.
Methods
: One hundred one patients (63 males and 38 females; mean age, 63.7±10.5 years) undergoing conventional coronary angiography were included in this study. All coronary arteries, including the distal segments and side branches, were analyzed for the presence of significant stenosis (≥50% diameter stenosis) and compared with of the quantitative coronary angiographic findings.
Results
: Of the 1,440 coronary artery segments studied, 1,348 segments were assessed quantitatively by both MDCT and conventional coronary angiography (94%). Two hundred nine significant stenoses were detected by conventional coronary angiography. On a segment-based analysis, the senisitivity, specificity, and positive and negative predictive values of 64-slice MDCT were 96, 97, 85, and 99%, respectively. On a vessel-based analysis, the sensitivity, specificity, and positive and negative predictive values of 64-slice MDCT were 96, 97, 85, and 99%, respectively. The corresponding values obtained on a patient-based analysis were 100, 94, 97, and 100%, respectively. Coronary calcification was the major cause of false-positive findings.
Conclusions
: This study demonstrated that 64-slice MDCT coronary angiography is of similar accuracy as conventional coronary angiography for the detection of coronary artery disease. In selected groups of patients, 64-slice MDCT may replace the more invasive coronary angiography. (Korean J Med 75:42-53, 2008)
Key Words : Spiral volumetric computed tomography; Coronary angiography; Coronary artery disease
Keywords :Spiral volumetric computed tomography, Coronary angiography, Coronary artery disease